AMERICAN-BUILT POWER DISTRIBUTIONSAN ANTONIO & SOUTH TEXAS / NATIONWIDE SHIPPING

BUILT IN THE USA. READY FOR YOUR PROJECT.

Request Switchgear Pricing

A useful switchgear pricing request describes the electrical system and the job around it, not just the desired amperage.

DIRECT FROM THE MANUFACTURER / NEW EQUIPMENT

Tall gray switchgear cabinets with circuit breakers and orange labels on pallets.
01 / POWER DISTRIBUTIONBUILT FOR THE JOB
Representative switchgear photography.
✦MADE IN THE USAAmerican components
▦UL 891Switchboards when specified
↗BUILT TO SPECProject-specific engineering
→NATIONWIDEShipping across the USA

THE MANUFACTURER’S PERSPECTIVE — 02

A useful switchgear pricing request describes the electrical system and the job around it, not just the desired amperage. Owners, electrical contractors, and engineers can obtain a more meaningful proposal by sharing the same drawings, installation constraints, and documentation expectations. A direct manufacturer can then identify design assumptions and questions before the scope becomes a purchase commitment.

Describe what the assembly needs to do

Start with the project location, intended application, and whether the equipment will serve a new installation or replace a lineup as part of a site upgrade. Identify the purchaser, engineer, installing contractor, and decision maker if known. A short operating description helps distinguish essential distribution from optional metering, transfer, or monitoring functions.

Include the latest single-line diagram and load schedule, marked with their revision dates. Show incoming sources, main and tie devices, feeder destinations, and any anticipated additions. If drawings are incomplete, distinguish established requirements from estimates: a budgetary request based on preliminary information should not be mistaken for a fully engineered purchase specification.

Provide electrical duty and protection data

State the system voltage, phase and wire configuration, frequency, grounding arrangement, load demands, and required continuous current. Supply available fault-current information at the proposed equipment location and identify its source and date. The engineer and manufacturer must evaluate device interrupting capability and assembly short-circuit duty against the actual system, not an assumed value.

List protective devices and functions, including required coordination, ground-fault protection, and control power. Share relevant studies or the criteria for studies still in progress. The request should say who supplies settings and performs coordination analysis; a quoted breaker with a particular trip unit does not by itself establish selective coordination throughout the system.

Define physical and utility interfaces

Provide a room or site layout, equipment footprint constraints, desired indoor or outdoor location, ambient conditions, and environmental exposures. Note doorways, access paths, and any limits on shipping sections. The installer and design team must confirm required working clearances, ventilation, anchorage, and service access; a compact lineup may constrain future connections or maintenance.

For each incoming and outgoing circuit, identify the number and size of conductors, top or bottom entry, and any busway or transformer connection. Where service equipment is involved, share utility requirements for metering, terminations, and approvals. These details affect enclosure space and interfaces, so changes after design review can affect both scope and schedule.

Specify the proposal and submittals

Ask for an itemized scope identifying the assembly, principal devices, control features, and any factory testing. Request a preliminary drawing package and a list of assumptions, exclusions, and exceptions as appropriate to the proposal stage. Clarify whether final shop drawings, wiring diagrams, test reports, and operating manuals are included and when each will be delivered.

Identify the applicable equipment standards and any required third-party listing in the specification. UL 891 may be relevant to an appropriate switchboard assembly, but it is not a blanket designation for all switchgear. Verify the proposed assembly’s actual listing and its scope against the project requirements and authority having jurisdiction before acceptance.

Compare pricing on the same scope

A lower initial figure can reflect fewer feeders, different protective functions, less documentation, or excluded freight rather than an equivalent design. Ask for alternatives to be clearly separated from the base offer, with device descriptions and design exceptions identified. Compare the proposed electrical duties, enclosure conditions, testing, and delivery terms before treating two quotations as interchangeable.

Confirm the boundaries between manufacturer and contractor: unloading, rigging, foundations, field connections, protection settings, site testing, and commissioning may be separately assigned. Ask how freight, shipping splits, warranty terms, taxes, and revisions are addressed. Keep unresolved items in a written clarification log so that procurement and the project engineer can assess their financial and technical consequences.

Plan review and delivery milestones

Give the desired quotation date, required site delivery date, and any outage or construction milestones, while identifying their flexibility. Request a proposed sequence for technical review, drawing approval, component procurement, fabrication, inspection, and shipment. Component availability and the speed of approvals can change the schedule, so confirm assumptions rather than treating an early estimate as a firm delivery commitment.

Name the people responsible for approving revisions and receiving equipment, and explain how design changes will be priced and documented. For a replacement project, the owner and qualified electrical professionals should coordinate surveys, isolation, installation, testing, and energization under the site safety plan. A quotation is a planning tool, not authorization to perform electrical work.

LET'S BUILD SOMETHING RELIABLE — 03

Ready to talk
switchgear?

Tell us about the new equipment your project needs. Include as much or as little detail as you have today.

(951) 403-5738

CALL TO DISCUSS YOUR PROJECT

PROJECT INQUIRY

Request a quote

01 — 04

This opens your email app for you to review and send. Add any details that do not transfer, or call if you do not have an email app configured.

Request a quote