BUILT IN THE USA. READY FOR YOUR PROJECT.
Switchgear Quotes
A useful switchgear quote does more than attach a number to a one-line diagram.
DIRECT FROM THE MANUFACTURER / NEW EQUIPMENT

THE MANUFACTURER’S PERSPECTIVE — 02
A useful switchgear quote does more than attach a number to a one-line diagram. It defines the new assembly being offered, the information behind its design, and the work that remains with others. Owners, contractors, and engineers can compare offers more confidently when each manufacturer prices the same electrical, physical, and documentation requirements.
Give bidders the same design basis
Start with the latest one-line diagram, load schedule, project specifications, and the planned equipment location. Identify each source, main device, feeder, and expected future circuit. Note the system voltage, phase and wire configuration, and required continuous current. If the drawings are preliminary, identify the revision and mark decisions still open.
Describe the facility’s operating priorities, too. A lineup serving process loads may need a different arrangement from one where the owner can schedule an extended shutdown. Distinguish a spare breaker that must be supplied now from reserved space for a possible future circuit; the two requests have different material and engineering implications.
Make electrical duty and protection comparable
Provide available fault-current information and the source assumptions behind it, including utility information or a study when available. Ask each bidder to state the proposed assembly short-circuit duty and protective-device interrupting ratings. Continuous current alone does not establish fault suitability, and device ratings must be evaluated within the proposed assembly.
Specify protection functions, metering, control power, communications, and any required interlocks. Identify who will complete the coordination study and provide settings. For an applicable switchboard, identify any required UL 891 listing and ask for confirmation that the proposed configuration falls within its listing; do not assume that standard applies to every switchgear assembly.
Show the physical and connection interfaces
Include the available footprint, access route, installation environment, and desired cable entry. Conductor material, sizes, quantities, termination preferences, and connections to transformers or busway can change the internal layout. A compact bid is not an advantage if cable bending space, working access, or equipment removal cannot be accommodated.
State whether the enclosure is indoors or outdoors and describe conditions such as moisture, corrosive exposure, ambient heat, or altitude. Request the proposed dimensions, shipping splits, weights, and anchorage information as design develops. The project design team must verify clearances, ventilation, support, and other site-specific requirements.
Separate equipment scope from field work
A direct manufacturer’s proposal should identify the new assembly and included devices, internal wiring, documentation, and any factory checks. Ask whether freight, unloading, field connections, and assistance at startup are included or excluded. Identify responsibility for foundations, conduit, external cables, utility coordination, permits, and independent testing rather than relying on assumptions. If factory acceptance testing is required, define which functions are witnessed, how acceptance criteria are agreed, and who receives the records. Distinguish routine inspection from a witnessed test; their scope and scheduling impact need not be the same.
For a replacement project, provide verified interface information from the existing installation and identify the owner’s outage constraints. The quote should distinguish manufacturing from the contractor’s installation and the owner’s switching plan. A qualified project team must assess isolation, temporary power, protection settings, and energization under applicable procedures.
Review submittals, exceptions, and commercial terms
Request an equipment schedule, preliminary one-line or other stated proposal drawings, an itemized scope, and a written list of exceptions. After order, agree on which shop drawings, device information, test records, and manuals will be delivered and when they will be submitted. Approval drawings should resolve interfaces before fabrication is released.
Compare each offer against one requirements matrix, not just its total. Check device functions, enclosure, testing, freight terms, warranty, taxes, and optional items; an exclusion may explain an apparent difference. If domestic component origin is specified, request item-level confirmation and availability rather than assuming every component has the same origin.
Tie the quotation to a workable schedule
Give the manufacturer the desired submittal, approval, delivery, and installation milestones, along with the jobsite destination. Ask what starts the quoted manufacturing schedule, what information is needed for release, and whether component availability has been checked. A quoted estimate is a planning input, not a delivery guarantee.
Assign a single owner for consolidating review comments and tracking design revisions. Changes after approval may affect material commitments, cost, drawings, and delivery; require a written change proposal before proceeding. Coordinate delivery and commissioning with qualified personnel, the installing contractor, the utility where applicable, and the facility’s authorized representatives.
LET'S BUILD SOMETHING RELIABLE — 03
Ready to talk
switchgear?
Tell us about the new equipment your project needs. Include as much or as little detail as you have today.
(951) 403-5738CALL TO DISCUSS YOUR PROJECT