Electrical Panelboards for Oil and Gas

In an oil and gas facility, a panelboard is often the last distribution point before power reaches lighting, receptacles, instrumentation and smaller process loads.

DIRECT FROM THE MANUFACTURER / NEW EQUIPMENT

Switchgear cabinets loaded on a flatbed truck outdoors.
01 / POWER DISTRIBUTIONBUILT FOR THE JOB
Representative switchgear photography.
✦MADE IN THE USAAmerican components
▦UL 891Switchboards when specified
↗BUILT TO SPECProject-specific engineering
→NATIONWIDEShipping across the USA

THE MANUFACTURER’S PERSPECTIVE — 02

In an oil and gas facility, a panelboard is often the last distribution point before power reaches lighting, receptacles, instrumentation and smaller process loads. Its location can simplify field wiring, but exposure, hazardous-area classification and operator access may make a nearby location unsuitable. Owners and specifiers should resolve those constraints alongside the electrical schedule before requesting a new assembly.

Map branch circuits to the process

Start with a one-line diagram and a panel schedule showing each load, operating demand, circuit configuration and destination. Identify heat tracing, instrument power, skid auxiliaries, lighting and receptacles separately so that critical services are not obscured by a single allowance. Note planned additions and the operating assumptions behind spare ways.

Panelboards can feed suitable individual motor circuits, but motor starting and control may require additional equipment. Where a site has many controlled motors, compare a motor control center with a panelboard and separate starters or drives. The engineer should review starting current, feeder voltage drop, overload protection and the division of responsibilities at each skid.

Let area classification guide placement

Obtain the current hazardous-area classification drawings, including the applicable class, division or zone and material group for the proposed location. A general-purpose enclosure is not automatically suitable just because it is weather resistant. The project engineer and authority having jurisdiction must determine whether the complete assembly and its installation are appropriate for the classified location.

Locating the panelboard in an appropriately designed electrical room or other unclassified area may simplify equipment selection and routine access, but it can lengthen branch circuits and change cable routing. Compare those costs with a classified-location solution, including required equipment approvals, entry arrangements and space. Confirm the final boundary and approach before committing to a layout.

Check the source and protection together

Provide the system voltage, phase and wire configuration, grounding arrangement, feeder size and available fault current at the panelboard. Include contributions from normal and alternate sources where applicable. The selected assembly, its devices and their interrupting or short-circuit ratings must be suitable for the actual system and installation, not simply the expected load current.

Give the protection-study engineer device details and upstream protective information early enough to assess coordination across the relevant fault range. Motor starting, drive characteristics and sensitive instrumentation can influence branch protection decisions. A spare circuit position does not by itself establish capacity for a future load; bus capacity, protection and the upstream feeder also need review.

Design for the real environment

Describe whether the panelboard will face direct sun, rain, dust, washdown, salt-bearing air, chemical vapors or temperature swings. The enclosure, finish, hardware and cable-entry design should match the specified exposures and any hazardous-area requirements. An outdoor enclosure choice alone does not establish corrosion resistance or suitability for every chemical atmosphere.

Heat and condensation require their own review. Identify ambient conditions, internal losses and any available room ventilation, and ask how the proposed assembly maintains acceptable operating conditions without compromising its intended enclosure protection. Humidity control or heating provisions may be appropriate, subject to the equipment design and site classification.

Coordinate cables and operator access

Show the preferred feeder and branch-circuit entry paths, conductor sizes and quantities, grounding connections, and any segregation requirements for power and controls. The manufacturer and installer can then review termination space, bending room and field interfaces against the assembly drawings. Classified-area wiring methods and entry fittings must be selected and installed by qualified personnel under the project requirements.

Review the actual room or shelter layout for required working clearances, door swing, lighting, equipment identification and a practical route for personnel and materials. A panel placed close to a process skid may reduce cable length yet be difficult to access during normal operations. The owner should identify restricted areas and maintenance access expectations before drawings are approved.

Purchase against an agreed scope

For a meaningful direct-manufacturer quotation, submit the one-line, panel schedule, classification drawings, environmental criteria, dimensions and target milestones. Specify applicable codes, panelboard listing requirements and inspection needs; verify the proposed assembly's listing and scope for the project rather than assuming any particular approval. Identify any component-origin requirements and confirm sourcing and availability.

Request a submittal package that identifies circuit and device schedules, ratings, enclosure details, dimensions, cable interfaces, deviations and proposed inspection records. Agree who supplies field wiring, settings, installation and commissioning, and allow time for drawing review, component procurement and site coordination. Qualified electrical personnel must plan and perform field work under applicable codes, manufacturer instructions and site safety procedures.

LET'S BUILD SOMETHING RELIABLE — 03

Ready to talk
switchgear?

Tell us about the new equipment your project needs. Include as much or as little detail as you have today.

(951) 403-5738

CALL TO DISCUSS YOUR PROJECT

PROJECT INQUIRY

Request a quote

01 — 04

This opens your email app for you to review and send. Add any details that do not transfer, or call if you do not have an email app configured.

Request a quote